Filter Results By:

Products

Applications

Manufacturers

Showing results: 136 - 150 of 209 items found.

  • 1000W Ferroresonant Power Supply

    Series PRR - Kepco, Inc.

    Kepco's PRR are 1000 Watt rack mounted laboratory systems power supplies that offer the low cost and very high dependability of ferroresonant voltage stabilization.The ferroresonant stabilizing technique provides extraordinary isolation from a wide variety of source noise. It is inherently short-circuit proof and cannot expose delicate loads to overvoltage hazards. Hence no crowbar, fuses, or bounding circuits are needed. Ferroresonant power supplies use no noise-producing switches or oscillators. Voltage setting is independent of delicate control settings or diode references and requires no comparators, references, or limiters. Efficiency is 70-80%.

  • 16-Channel DAC FMC Module

    FMC216 – HPC - Sundance Multiprocessor Technology Ltd.

    The FMC216 is a sixteen-channel DAC FMC Daughter Card which is fully compliant with the VITA 57.1-2008 standard. The FMC216 provides sixteen D/A 16-bit 312.5Msps (2.5Gsps with x8 interpolation) channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC216 has the HPC (high-pin count) connector, front panel I/O, and is conduction cooled capable.

  • Meter Test System

    MTS-122 - Kongter Test & Measurement Co., Limited

    This rugged Meter Test System is composed of high accurate (class 0.05% or 0.1%) standard reference meter and power source (up to 36A). This system is particularly designed with modular structure for calibration and test of analog meter, digital meter, RTU, electrical transducer, energy meter and so on. It is operated under high functionality with user friendly interface.

  • Optical Power and Wavelength Meter

    OMM-6810B - Newport Electronics

    The OMM-6810B is a power and wavelength meter capable of simultaneously measuring the optical power and wavelength of a laser source. A wide variety of measurement heads cover wavelength ranges from 350 to 1650 nm for power ranges of up to +40dBm or 10W.This meter has standard features such as logarithmic or linear display modes, auto ranging, user calibratable offset, reference measurement capability, analog output and IEEE-standard GPIB interface to make this instrument a cost effective laser diode development or production test tool.

  • Sound Level Calibrator

    521 - ACO Pacific, Inc.

    Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.

  • Sound Level Calibrator

    511E - ACO Pacific, Inc.

    Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.

  • 2-Channel DAQ Module

    FMC142 - Sundance Multiprocessor Technology Ltd.

    The FMC142 is an analog-to-digital (A/D) and digital-to-analog (D/A) FMC daughter card that provides two 16-bit A/D channels at 370MSPS and two 16-bit D/A channels at 2.5GSPS which can be clocked by an internal clock source (optionally locked to an external reference) or by an externally-supplied sample clock. A trigger input is also available for customized sampling control. The FMC142 is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1-2010). It offers front panel analog I/O access and can be used in a conduction-cooled environment.

  • 4-Channel DAQ Module

    FMC176 - Sundance Multiprocessor Technology Ltd.

    The FMC176 is a quad channel ADC and dual channel DAC FMC. This daughter card provides four 14-bit A/D channels at 250Msps and two 14-bit D/A channels at 5.6Gsps (2.8Gsps direct RF synthesis) clocked by either an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition, a trigger input for customized sampling control is available to users. The FMC176 daughter card is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).

  • Pressure Balances

    WIKA Alexander Wiegand SE & Co. KG

    Pressure balances (often also referred to as mechanical dead-weight testers or primary standards) are the most accurate reference instruments for pressure. Their functional principle is based on the physical principle of pressure = force/area. Mass pieces placed on the top of a piston-cylinder system are the source of a precisely defined force. By producing a certain (counter) pressure inside the pressure balance an equilibrium is achieved: the mass pieces, including the free-running piston of the piston-cylinder system, are floating, which will lead to a very accurate pressure at the test port.

  • Primary Standards

    Mensor Corp.

    Primary standards (often also referred to as mechanical dead-weight testers or pressure balances) are the most accurate reference instruments for pressure. Their functional principle is based on the physical principle of pressure = force/area. Mass pieces placed on the top of a piston-cylinder system are the source of a precisely defined force. By producing a certain (counter) pressure inside the primary standard an equilibrium is achieved: the mass pieces, including the free-running piston of the piston-cylinder system, are floating, which will lead to a very accurate pressure at the test port.

  • 10 GHz Signal Source

    YIG Series - SignalCore, Inc.

    The SC5503B and SC5502A are designed to meet demanding low phase noise applications. This is accomplished by employing a multiple phase-locked loop architecture as well as a YIG oscillator as the heart of its synthesizer. Frequency accuracy is provided by an onboard 10 MHz temperature compensated crystal oscillator (TCXO) which can be phase locked to an external reference source if required. These modules can be used as standalone CW signal sources or as LO sources for frequency conversion systems such as the SignalCore IQ modulators and demodulators. They are designed to meet the requirements of many modern applications such as wireless device testing, software-defined radio research, point-to-point radio, multi-channel coherent systems, and other academic and military programs.

  • EMC / RF Test System Engineering / Development & Integration

    EMC Instruments Corporation

    Anechoic chamber, radio isolation room construction, removal, maintenance and repair. System Integration of complete Test System. Development team has the expertise and technical experience and provide a customized service demand, the project includes a full range of EMI / EMS / RF test equipment with neighboring sell and repair reference signal source Noise Generators Signal Generators

  • Meter Testing System

    ASTel - Radian Research, Inc.

    Three-phase Meter Test Equipment of ASTeL 3.2x.x series system is a fully automatic system enabling simultaneous, multi-position calibration and legalization of electric energy meters. The automatics include power sources, reference standards, stand controllers, photoelectric scanning heads, separating transformers, and other elements of the system. All these elements are controlled through a Windows based executive program.

  • 4-Channel ADC FMC Module

    FMC103 – LPC - Sundance Multiprocessor Technology Ltd.

    The FMC103 is a four-channel ADC FMC (FPGA Mezzanine Card) which is fully compliant with the VITA 57.1-2010 standard. The FMC103 card provides four 12-bit 210 MSPS A/D channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC103 has the LPC (Low-Pin Count) 160-Pin connector, front panel I/O, and is conduction cooled compliant. The board is also available with Mil-I-46058c compliant Conformal Coating.

  • 8-Channel ADC Module

    FMC107 - Sundance Multiprocessor Technology Ltd.

    The FMC107 is an eight-channel ADC FMC (FPGA Mezzanine Card) which is fully compliant with the VITA 57.1-2010 standard. The FMC107 card provides eight 12-bit 65 MSPS A/D channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC107 has the LPC (Low-Pin Count) 160-Pin connector, front panel I/O, and is conduction cooled compliant. The board is also available with Mil-I-46058c compliant Conformal Coating.

Get Help